Milk cooling tanks open- tube version are manufactured in versions 2 and 4 milkings of capacity 1000,1200, 1600 and 2000 liters.

Description

The milk cooling tanks work in the direct expansion of cooling system as follows the milk is cooled directly by walls of evaporator that is placed on the bottom of the tank.

 

 

The milk cooling tank in version 2 milking- is destinated to precool of milk in two portion it means every day. Used refrigerating units can make possible precool of ½ of capacity tank during max. 3 hours with temperature 35 °C to 4 °C ( effective time of pre-cool of first portion of milk is shorter then 2,5h)

 

 

 

 

The milk cooling tank in version 4 milking- is destinated to pre-cool of milk in four portion it means every second day. Used refrigerating units can make possible pre-cool of 1/4 of capacity tank during max. 3 hours with temperature 35 °C to 4 °C ( effective time of pre-cool of first portion of milk is shorter then 2,5h).

 

 

 

In milk cooling tanks, there is the refrigerant tank in the cooling system and the thermostatic expansion valve that allows precise dose refrigerant to evaporator according to requirements. This has a direct impact on reducing operating costs and extends the life of the refrigerating unit.

 

USABLE ADVANTAGES MILK COOLING TANKS

 

High efficency of refrigerating system.

Special construction of evaporator (honeycomb) made with laser welding process, that increases the fatigue strength of evaporator and influence longer life of evaporator, high quality of refrigerating unit and cooling automatics,

The condenser fan speed control

Shape of blades and rotation of agitator.

Very low energy consumption.

The energy consumption does not exceed 0,015-0,017 kW/l for cooling 1 liter of milk at the ambient temperature 32°C.

Reliability useing

The maintenace of milk cooling tanks – simply steps:

- connecting of hose's end into miliing installation

- setting switch off on the control board

- open and close the drain valve

Ecological refrigerant.

Very good thermal insulation.

The temperature rise of stored milk when the refrigerating unit is switched off , the temperature does not exceed 0,5oC during 4 hours,

Ecological thermal insulation.

The insulation is made with polyurethane foam process without freon.

Modern electronic controlling enables:

- Automatic control and monitoring of the process of milk cooling and storage
- Automatic programmed control of the full cleaning process:
* pre-rinse
* Fundamental clean with detergents
* Final rinse
- The ability to create your own cleanning program
- Indication of status and fault conditions
- Periodic mixing of the cooled milk during storage ( when the refrigerating unit doesn't work)time of mixer working 4 minutes , time of break 40 minutes
 

The whole tank with its equipment is made of stainless steel ( excepting frame and refrigerating unit)

- Using of stainless, acid-proof steel enables User to keep easily a good hygiene conditions of milk cooling tanks.